3RF3410-1BB26
SOLID-STATE CONTACTOR 3-PH 3RF3

From SIEMENS

Solid-state contactor 3-phase 3RF3 AC 53 / 9.2 A / 40 °C 48-600 V / 110-230 V AC 2-phase controlled Instantaneous switching screw terminal
General technical data
Product brand nameSIRIUS
Product designation _2 of the accessories that can be orderedConnection adapter
Product designation _1 of the accessories that can be orderedLink module
Manufacturer's article number
_1 of the accessories that can be ordered
_2 of the accessories that can be ordered
Protection class IPIP20
Insulation voltage rated valueV600
Installation altitude at height above sea level maximumm1 000
Ambient temperature
during storage°C-55 ... +80
during operation°C-25 ... +60
Shock resistance acc. to IEC 60068-2-2715g / 11 ms
Vibration resistance acc. to IEC 60068-2-62g
Surge current resistance rated valueA600
Power loss [W] total typicalW16
Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750K
Reference code acc. to DIN EN 61346-2Q
Product functioninstantaneous switching
Main circuit
Number of poles for main current circuit3
Number of NO contacts for main contacts2
Operating frequency rated valueHz60 ... 50
Operating voltage at AC
at 60 Hz rated valueV48 ... 600
at 50 Hz rated valueV48 ... 600
Operating current
minimummA500
at AC-53a at 400 V at ambient temperature 40 °C rated valueA9.2
Operating range relative to the operating voltage at AC
at 50 HzV40 ... 660
at 60 HzV40 ... 660
Operating power at AC-3 at 400 V rated valuekW4
Derating temperature°C40
Symmetrical line frequency toleranceHz5
Relative symmetrical tolerance of the operating frequency%10
I2t value maximumA²·s1 800
Rate of voltage rise at the thyristor for main contacts maximum permissibleV/µs1 000
Blocking voltage at the thyristor for main contacts maximum permissibleV1 600
Reverse current of the thyristormA10
Control circuit/ Control
Type of voltage of the control supply voltageAC
Control supply voltage frequency
1 rated valueHz50
2 rated valueHz60
Relative symmetrical tolerance
of the control supply voltage frequency%10
of the supply voltage frequency%10
Control supply voltage 1
at AC
— at 50 Hz Initial rated valueV110
— at 50 Hz Final rated valueV230
— at 60 Hz Initial rated valueV110
— at 60 Hz Final rated valueV230
Operating range factor control supply voltage rated value
at AC at 50 Hz0.82 ... 1.1
at AC at 60 Hz0.82 ... 1.1
Control supply voltage at AC
initial value for signal <1> detectionV90
at 50 Hz Full-scale value for signal<0> recognitionV40
at 60 Hz Full-scale value for signal<0> recognitionV40
Control current
at AC rated valuemA15
at minimum control supply voltage
— at ACmA2
switching times
ON delay5 ms
OFF delay30 ms + in addition max. one half-wave
Installation/ mounting/ dimensions
Mounting positionvertical
Mounting typescrew and snap-on mounting onto 35 mm standard mounting rail
Mounting type Side-by-side mountingYes
Tightening torque of the screw for securing the equipmentN·m1.5
Design of the thread of the screw for securing the equipmentM4
Widthmm90
Heightmm95
Depthmm100.8
Required spacing with side-by-side mounting
upwardsmm70
downwardsmm50
Connections/Terminals
Type of electrical connection
for main current circuitscrew-type terminals
for auxiliary and control current circuitscrew-type terminals
Design of the thread of the connection screw
for main contactsM4
of the auxiliary and control contactsM3
Product function removable terminal for auxiliary and control circuitYes
Type of connectable conductor cross-sections
for main contacts
— solid2x (0.5 ... 2.5 mm²)
— finely stranded
— with core end processing2x (0.5 ... 1.5 mm²)
at AWG conductors
— for main contacts2x (18 ... 14)
— for auxiliary and control contacts1x (AWG 20 ... 12)
for auxiliary and control contacts
— solid1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
— finely stranded
— with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
— without core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
Tightening torque
for main contacts with screw-type terminalsN·m2 ... 2.5
for auxiliary and control contacts with screw-type terminalsN·m0.5 ... 0.6
Tightening torque [lbf·in]
for main contacts with screw-type terminalslbf·in18 ... 22
for auxiliary and control contacts with screw-type terminalslbf·in7.5 ... 5.3
Wire stripping length of the cable
for main contactsmm7
for auxiliary and control contactsmm7
UL/CSA ratings
Full-load current (FLA) for three-phase AC motor
at 480 V rated valueA4.8
at 600 V rated valueA6.1
Yielded mechanical performance [hp] for three-phase AC motor
at 200/208 V rated valuehp1.5
at 220/230 V rated valuehp2
at 460/480 V rated valuehp3
at 575/600 V rated valuehp5