3RA2130-4UA35-0AP0
L. FEEDER DS 100KA S2, 32-40A, 230VAC

From SIEMENS

Load feeder fuseless, Direct-on-line starting 400 V AC, Size S2 32...40 A 230 V AC, 50 Hz screw terminal for installation on standard mounting rail (also fulfills type of coordination 1) Type of coordination 2, Iq = 100 kA 1 NO+1 NC (contactor)
Product brand nameSIRIUS
Product designationDirect (on-line) starter
Design of the productfor standard rail or screw mounting
Product type designation3RA21
Manufacturer's article number
of the supplied contactor
of the supplied circuit-breakers
of the supplied link module
General technical data
Size of the circuit-breakerS2
Size of load feederS2
Insulation voltage
with degree of pollution 3 rated value690 V
Surge voltage resistance rated value6 kV
Protection class IP
on the frontIP20
of the terminalIP00
Shock resistance
acc. to IEC 60068-2-276g / 11 ms
Mechanical service life (switching cycles)
of contactor typical10 000 000
Type of assignment2
Protection against electrical shockfinger-safe when touched vertically from front acc. to IEC 60529
Ambient conditions
Temperature compensation-20 ... +60 °C
Relative humidity during operation10 ... 95 %
Main circuit
Number of poles for main current circuit3
Design of the switching contactelectromechanical
Adjustable pick-up value current of the current-dependent overload release32 ... 40 A
Operating voltage
rated value690 V
at AC-3 rated value maximum690 V
Operating frequency rated value50 ... 60 Hz
Operating current
at AC-3
— at 400 V rated value35 A
Operating power
at AC-3
— at 230 V rated value11 000 W
— at 400 V rated value18 500 W
Control circuit/ Control
Type of voltage of the control supply voltageAC
Control supply voltage at AC
at 50 Hz rated value230 V
Apparent holding power of magnet coil at AC16 V·A
Inductive power factor with the holding power of the coil0.37
Auxiliary circuit
Product extension Auxiliary switchYes
Protective and monitoring functions
Trip classCLASS 10
Design of the overload releasethermal (bimetallic)
Response value current
of instantaneous short-circuit trip unit585 A
Short-circuit protection
Product function Short circuit protectionYes
Design of the short-circuit tripmagnetic
Conditional short-circuit current (Iq)
at 400 V acc. to IEC 60947-4-1 rated value100 000 A
Installation/ mounting/ dimensions
Mounting positionvertical, horizontal
(mounting type)Screw-fixing and snap-on mounting to two 35 mm standard mounting rails
Height274 mm
Width55 mm
Depth150 mm
Required spacing
for grounded parts
— forwards32 mm
— Backwards0 mm
— upwards50 mm
— at the side10 mm
— downwards10 mm
for live parts
— forwards32 mm
— Backwards0 mm
— upwards50 mm
— downwards10 mm
— at the side10 mm
Connections/Terminals
Type of electrical connection
for main current circuitscrew-type terminals

External links